Стартер 24V 6KW 12T M93R3002SE для Cummins 4B, 4BT, 4BTA, 6B и 6BT дизель двигатели
Применимый тип:For Cummins 4B, 4BT, 4BTA, 6B и 6BT дизель двигатели (also EQB / BGE / IE platforms)
Номер запчасти:M93R3002SE, M93R3001SE, C4948058, C4983774, C4935789, 4929600.
| Мощность л.с. : | 28V 6KW |
| Число футов : | 12T |
| Размер : | 44*24*19 cm single unit inner box |
| Вес : | Вес нетто 10,2 кг, вес брутто 10,75 кг |
| Упаковочные материалы : | Нейтральная упаковка из крафт-бумаги |
| Спотовые / предварительные продажи : | В наличии |
| Гарантия : | 1 год |
| Номер продукта : |
| Тип : | стартер |
| Спецификация : | 24V 6KW |
| Число футов : | 12T |
| Марка : | nuojin |
| Цифры : | M93R3002SE M93R3001SE |
| Качество : | НОВЫЙ |
| Время поставки : | 30 дней |





Overview of the M93R3002SE Starter Motor
This M93R3002SE starter motor is the 24V, 6 kW replacement for Cummins 4B, 4BT, 4BTA, 6B and 6BT diesel engines applications. The housing, drive end and terminal positions follow the original design, so the unit bolts straight onto the bell housing and reuses the existing cabling.
Because the motor is only used in short bursts, heat builds up quickly and escapes slowly. A starter that has worked for years in traffic or on site will show heat-hardened resin, shortened brushes and a pitted solenoid contact long before the windings fail.
Key Specifications
- Rated voltage: 24V
- Rated output: 6 kW
- Pinion: 12 teeth
- Type: reduction gear starter with pre-engaged solenoid
- Application: Cummins 4B, 4BT, 4BTA, 6B and 6BT diesel engines
- Net weight: approximately 10.75 kg
- Condition: new, direct replacement for the original unit
A 24V 6 kW rating is the output the motor can hold while cranking, not a peak figure. It is sized so the engine reaches starting speed on the first or second revolution, which is what makes a healthy start feel immediate.
The drive end housing is cast aluminium and carries the pinion bearing, so the pinion stays square to the ring gear when the motor delivers full torque.
Reference Numbers and Cross References
The starter is supplied against the following references, which help identify it against the unit already fitted to the vehicle:
- M93R3002SE
- M93R3001SE
- C4948058
- C4983774
- C4935789
- 4929600
Cross references are a guide, not a fitment guarantee. The same engine family was often built with more than one starter, and the pinion module or terminal bracket can differ between them, so confirm the number on the unit being replaced. This starter is listed with 6 references in total.
Application Notes
The unit is listed for Cummins 4B, 4BT, 4BTA, 6B and 6BT diesel engines. Because manufacturers changed starter suppliers during the production run, the safest check is the number stamped on the starter body, not the model year alone. Fitting the M93R3002SE correctly takes less time than diagnosing the original fault.
If the number on the old unit falls outside the list above, send the engine code and a photograph of the drive end before ordering. A starter with the correct housing but the wrong pinion will grind on the first attempt and can chip the ring gear.
Why These Starters Fail
The brush plate is the second common failure point. Brushes shorten gradually, spring pressure falls, and contact becomes intermittent. Cranking speed drops a little every week until the engine refuses to start on a cold morning.
Heat is the underlying cause in most cases. The starter sits close to the exhaust, and after a hot shutdown the solenoid winding and brush plate soak in heat with no airflow. Resin hardens, springs lose tension and the contact oxidises. Because the M93R3002SE reuses the original bolts and connectors, no adapters are needed on Cummins 4B, 4BT, 4BTA, 6B and 6BT diesel engines.
Diagnostic Signs
- A single heavy click, then nothing
- Slow, laboured cranking from cold that improves once the engine runs
- Metallic scrape or whine during cranking
- Starter that disengages late, with a brief screech after the engine fires
- Burning smell near the starter after a failed start attempt
A cranking voltage test separates the starter from the rest of the circuit. If battery voltage stays healthy at the terminals but drops sharply at the starter stud, the cable or the connection is at fault rather than the motor. This applies in particular to the M93R3002SE supplied for Cummins 4B, 4BT, 4BTA, 6B and 6BT diesel engines.
Pre-Fit Checklist
- State of charge and age of the battery
- Corrosion on the earth strap and the engine-to-body bond
- Pinion tooth count against the ring gear
- Free movement of the new pinion before fitting
- That the signal wire connector seats fully on the solenoid
Fitting a new starter onto a worn ring gear or a marginal battery shortens its life. Check the simple items first, then fit the unit once and correctly.
Installation Notes
Isolate the battery, mark the terminal positions, then disconnect the main cable and the signal wire. Clean around the mounting flange before the starter is withdrawn so dirt does not fall into the bell housing.
Clean the mounting face and inspect the ring gear teeth through the starter aperture. Fit the replacement with the original bolts, reconnect the cables in the same order and tighten the main terminal firmly. Crank the engine briefly and listen for clean engagement and release. The M93R3002SE is built to the same flange pattern as the unit it replaces.
Quality Control and Supply from Hejian Nuojin Auto Parts Co., Ltd.
Hejian Nuojin Auto Parts Co., Ltd. manufactures starter and alternator components for the aftermarket. Every unit is bench tested for no-load current draw, solenoid pull-in and release voltage, pinion throw and running noise before packing.
Standard references are held as spot goods, volume orders are delivered in around 30 days, and every unit carries a one-year warranty against manufacturing defects.
Frequently Asked Questions
Can the solenoid be replaced on its own?
It is possible, provided the motor draws normal current and the pinion is sound. Where the brushes are already short, replacing the complete starter avoids a second repair within a year.
Why does the starter work cold but fail when hot?
Heat raises solenoid resistance and reduces brush spring pressure. Both effects build up gradually and appear first on a hot restart.
Why does the starter click but not turn?
A click with no rotation usually means the solenoid pulls in but the contact does not pass current. Check the earth strap and the main cable before condemning the starter.
Does this starter come with the solenoid?
Yes. The unit is supplied complete with its solenoid, as shown in the product photographs. Mounting bolts are not included.