Стартер 12V 2.8KW 10T RE533976 для John Deere 5045D, 5055E, 5065E, и 5075E tractors
Применимый тип:John Deere 5045D, 5055E, 5065E, и 5075E tractors (2008–2014)
Номер запчасти:RE533976,F-002-G20-658,BF002G20658,300N12109Z F002G20658 RE544939 STB2065BA STB2065MN 17086N
| Мощность л.с. : | 12V 2.8KW |
| Число футов : | 10T |
| Размер : | |
| Вес : | Вес нетто 4,3 кг |
| Упаковочные материалы : | Нейтральная упаковка из крафт-бумаги |
| Спотовые / предварительные продажи : | В наличии |
| Гарантия : | 1 год |
| Номер продукта : |
| Тип : | стартер |
| Спецификация : | 12V 2.8KW |
| Число футов : | 10T |
| Марка : | NUOJIN |
| Цифры : | 17086N/ RE533976 |
| Качество : | НОВЫЙ |
| Время поставки : | 30 дней |







Overview of the RE533976 Starter Motor
The RE533976 starter motor is a 12V, 2.8 kW unit built for John Deere 5045D, 5055E, 5065E, and 5075E tractors. It is a reduction-gear starter with a pre-engaged solenoid, assembled to the original mounting flange and terminal positions so it fits without adapters or wiring changes.
The starter carries the full cranking current through its brushes and solenoid contact, so every start costs a little material. That is why the unit is normally replaced once, at the end of a long service life, rather than repaired repeatedly.
Key Specifications
- Rated voltage: 12V
- Rated output: 2.8 kW
- Pinion: 10 teeth
- Type: reduction gear starter with pre-engaged solenoid
- Application: John Deere 5045D, 5055E, 5065E, and 5075E tractors
- Net weight: approximately 4.3 kg
- Condition: new, direct replacement for the original unit
A 12V 2.8 kW rating is the output the motor can hold while cranking, not a peak figure. It is sized so the engine reaches starting speed on the first or second revolution, which is what makes a healthy start feel immediate.
The drive end housing is cast aluminium and carries the pinion bearing, so the pinion stays square to the ring gear when the motor delivers full torque.
Reference Numbers and Cross References
The reference family for this starter covers the numbers listed here:
- RE533976
- F-002-G20-658
- BF002G20658
- 300N12109Z
- RE544939
- 17086N
- 5045D
- 5055E
- 5065E
- 5075E
Several numbers in this list belong to complete starter assemblies while others refer to the motor only. A visual check of the drive end protects against the most common ordering error. This starter is listed with 10 references in total.
Matching the Unit to the Vehicle
This starter family was fitted to a range of John applications, and the part number changed as engines and flywheels were revised. The unit listed here covers the references above and is a direct replacement where those numbers match. Fitting the RE533976 correctly takes less time than diagnosing the original fault.
When ordering for a fleet, quote the starter number from each vehicle rather than a single model reference; mixed build dates are common and the starter changed with them.
What Wears Out First
Oil or coolant mist from a leaking seal finds its way into the drive end housing, mixes with carbon dust and forms a conductive paste. The starter then arcs internally and fails early, whatever its mileage.
The brush plate is the second common failure point. Brushes shorten gradually, spring pressure falls, and contact becomes intermittent. Cranking speed drops a little every week until the engine refuses to start on a cold morning. On John Deere 5045D, 5055E, 5065E, and 5075E tractors installations, access to the RE533976 usually decides how long the job takes.
What to Look For
- Cranking that sounds normal but takes longer than it used to
- Several attempts needed before the motor engages
- Black carbon dust inside the drive end housing
- Voltage dip that dims the lights during cranking
- Starter that responds to a tap on the housing but not to the key alone
A cranking voltage test separates the starter from the rest of the circuit. If battery voltage stays healthy at the terminals but drops sharply at the starter stud, the cable or the connection is at fault rather than the motor. Because the RE533976 reuses the original bolts and connectors, no adapters are needed on John Deere 5045D, 5055E, 5065E, and 5075E tractors.
What to Check Before Fitting
- Battery capacity under load, not just open-circuit voltage
- Terminal clamps and the main cable lug for corrosion or heat marks
- Earth strap between engine and chassis
- Ring gear teeth, visible through the starter aperture
- Key switch and signal wire voltage at the solenoid terminal
Most comebacks after a starter replacement trace back to something that was not checked before the unit went on: a tired battery, a corroded earth or a chipped ring gear. Ten minutes with a multimeter and a torch prevents the second repair.
Installation Procedure
Raise and support the vehicle where the starter is reached from below, disconnect the battery, and detach the main cable and signal wire. Note the cable positions before removal so the replacement goes back the same way.
Check the ring gear through the aperture before fitting. Install the new unit with the original bolts, reconnect the cables in the same order and tighten the main terminal without over-stressing the stud. Crank briefly and confirm the pinion releases as the engine fires. Where a RE533976 has been replaced before, check that the fitted unit still matches the reference list.
Quality Control and Supply from Hejian Nuojin Auto Parts Co., Ltd.
Each production batch is inspected for housing dimensions, terminal integrity and pinion fit, and every starter is bench tested before it is boxed. Units ship in neutral cartons with foam protection, which keeps freight damage low and allows distributors to label stock under their own brand.
Standard references are held as spot goods, volume orders are delivered in around 30 days, and every unit carries a one-year warranty against manufacturing defects.
Frequently Asked Questions
Why does the starter click but not turn?
A click with no rotation usually means the solenoid pulls in but the contact does not pass current. Check the earth strap and the main cable before condemning the starter.
How long should a replacement starter last?
Service life depends on starting frequency, battery condition and heat exposure. On a daily-driven vehicle with clean connections, ten years or more is realistic.
Is a 12V and a 24V starter interchangeable?
No. The voltage rating must match the vehicle system; fitting the wrong unit will damage the starter and the wiring.
Can I test the starter on the bench?
Yes. Apply battery voltage to the main stud and the signal terminal and check that the pinion throws and the motor turns. A clamp meter reading against the rated current will show whether the unit is drawing too much.