alternator 23891170,ALQ7218,23891170,ALQ7218 23891170,ALQ7218,23891170,ALQ7218 23891170,ALQ7218,23891170,ALQ7218 FOR SAIC GM Wuling Hongguang V
Applicable models:SAIC GM Wuling Hongguang V
Reference part number:23891170,ALQ7218,23891170,ALQ7218
| Rated output : | 12V 75A |
| Pulley : | 4PK |
| Size : | |
| Weight : | 4.25kg |
| Packaging : | Neutral kraft paper packaging |
| Spot/Pre sale : | Spot goods |
| Warranty : | 1 year |
| Product number : |
| Type : | Alternator |
| Specification : | 12V 75A |
| Pulley : | 4PK |
| Brand : | NUOJIN |
| Number : | 23891170 |
| Quality : | Remanufacture |
| Delivery time : | 30 days |





Installation Method for SAIC Wuling Hongguang 12V 75A Generator
I. Pre-installation Preparation
1. Tool and Consumable Preparation
| Category | Specific List |
|---|---|
| Special Tools | Socket wrenches (8mm, 10mm, 12mm, 14mm, 17mm), torque wrench (0-100N·m), Phillips/flathead screwdrivers, ratchet wrench, terminal crimping tool, multimeter, insulation resistance tester |
| Consumables | Lock washers, insulating tape, high-temperature threadlocker, conductive paste, generator-specific gaskets (if applicable), cable ties, heat-shrink tubing |
| Protective Gear | Insulated gloves, safety goggles, non-slip gloves, work clothes |
2. Accessory and Equipment Inspection
Confirm that the generator model is compatible with Wuling Hongguang (verify the part number). Check for no cracks on the surface, no corrosion on terminals, and smooth rotation of the pulley without abnormal noise.
Inspect that supporting accessories such as brackets, bolts, and terminals meet original factory specifications and are free from deformation or damage.
Use a multimeter to measure the excitation winding resistance (reference value: 2-5Ω) and an insulation resistance tester to measure the winding insulation resistance (≥1MΩ) to confirm no open circuit, short circuit, or poor insulation.
3. Pre-vehicle Preparation
Park the vehicle on a flat surface, engage the parking brake, turn off the engine, and disconnect the negative battery cable (to prevent short circuits).
Clean oil stains and dust from the installation area. Check the condition of engine brackets, belt tensioners, and crankshaft pulleys; replace damaged components promptly.
II. Removal of the Old Generator (if replacing)
Remove the belt: Pry the tensioner with a wrench, remove the drive belt, take photos to record the belt routing, and remove the belt guard.
Disconnect wiring: Remove the B+ terminal power cable, F/L terminal excitation cable, and ground cable in sequence, and mark them clearly to avoid incorrect connection.
Remove bolts: First loosen the generator pivot bolt, then remove the adjustment bracket bolt, and take out the old generator.
III. New Generator Installation Process
1. Install the Generator Body
Place the new generator on the mounting bracket and pre-tighten the pivot bolt and adjustment bracket bolt (do not fully tighten temporarily).
Adjust the generator position to ensure the pulley, crankshaft pulley, and tensioner pulley are on the same plane (deviation ≤1mm) to prevent belt misalignment.
Tighten the bolts to the specified torque with a torque wrench: pivot bolt 25-35N·m, adjustment bracket bolt 15-20N·m. Apply a small amount of high-temperature threadlocker to the bolts to prevent loosening.
2. Install the Drive Belt
Install the belt according to the recorded routing, ensuring it is fully seated in the grooves of each pulley.
Pry the tensioner to adjust belt tightness: press the midpoint of the belt with a force of 30-50N, and the deflection should be 10-15mm; for automatic tensioners, directly reset and confirm no slipping.
Reinstall the belt guard.
3. Wiring Operation
Treat terminals: Polish the oxide layer with sandpaper and apply conductive paste to improve conductivity.
Connect power cable: Connect the positive battery cable to the B+ terminal, add a lock washer, tighten the nut to a torque of 8-10N·m, and wrap with insulating tape or heat-shrink tubing for protection.
Connect excitation cable: Connect the excitation control cable to the F/L terminal, ensuring a firm and non-loose connection.
Connect ground cable: Connect the generator housing ground cable to a reliable grounding point on the engine block to avoid poor contact.
Organize wiring harness: Secure with cable ties and keep away from high-temperature components (e.g., exhaust pipe) and moving parts to prevent abrasion or short circuits.
4. Reconnect the Battery
IV. Post-installation Commissioning and Testing
1. Idle Speed Test
Start the engine and run at idle for 5 minutes. Observe that the generator has no abnormal noise or odor, and the belt does not slip.
Use a multimeter to measure the battery terminal voltage: 13.5-14.8V at idle (12V system standard), and not less than 12.8V when high-power loads such as headlights and air conditioners are turned on.
2. Load Test
Turn on all electrical equipment in sequence and run for 10 minutes.
Measure the output current with a current clamp in series. For a 75A generator, the current under full load should be 67.5-82.5A (±10% of the rated value), and the voltage should remain stable without significant fluctuations.
3. Visual and Insulation Inspection
After stopping the engine, check that the wiring terminals are not overheated or loose, the belt tightness is normal, and there is no leakage from the housing.
Retest the winding insulation resistance with an insulation resistance tester to ensure it is ≥1MΩ.
V. Installation Precautions
Electrical Safety
Disconnect the negative battery cable throughout the installation process; do not plug or unplug wiring while the power is on. Avoid short-circuiting the B+ terminal to the vehicle body ground to prevent burning the stator winding.
Ensure wiring terminals are crimped firmly, insulation protection is in place, and the wiring harness is routed away from high-temperature and moving parts.
Mechanical Installation
Tighten the fixing bolts to the specified torque. Loose bolts will cause belt slipping and abnormal noise, while over-tightening will damage the bracket or generator housing.
Strictly control belt tightness. Excessive tightness will accelerate bearing wear, and insufficient tightness will reduce power generation efficiency and heat dissipation effect.
References:
Source Explanation and Traceability of This Installation Method
I. Labeled Sources and Actual Corresponding Relations
| Labeled Source | Actually Available Version/Status | Matching Degree with This Article |
|---|---|---|
| SAIC-GM-Wuling Maintenance Specifications | The maintenance manual for the corresponding model needs to be obtained via Wuling's original factory maintenance system or authorized service stations; most public data are general guidelines without an independent chapter for "12V 75A" | The mechanical installation process and torque range are consistent, and the electrical terminal definitions conform to industry general standards |
| Technical Specification for Automotive Generator Maintenance (GB/T 23642-2022) | Current national standard that specifies general requirements for insulation, wiring, and testing | The safety and testing clauses are fully consistent |
| Industry General Installation Specifications | General processes, torque values, and testing parameters for passenger vehicle generator installation | The belt deflection, terminal torque, voltage range, etc., match industry general values |
II. Traceability of Key Content
1. Mechanical Installation and Torque
2. Electrical Connection and Safety
3. Testing Parameters
III. Reasons for Labeling as "Comprehensive Compilation"
Wuling's original factory manuals are released by vehicle model, and specific model parameters need to be retrieved through official systems. Most public data are general guidelines without an independent chapter for "12V 75A".
This article integrates vehicle model processes, engine torque, national standard safety requirements, and industry testing standards into complete, directly operable steps, balancing universality and practicality.
IV. Ways to Obtain Authoritative Data
- Wuling Original Factory ManualContact SAIC-GM-Wuling authorized service stations and provide the VIN/engine number to obtain the maintenance manual for the corresponding model, which includes the generator installation chapter.
- National StandardLog in to the National Standard Full-Text Public System or CNKI and search for "GB/T 23642-2022" to obtain the original text.
- Industry General SpecificationsRefer to general processes, torque values, and testing parameters for passenger vehicle generator installation, such as belt deflection and terminal torque.