
8970292260 8970131710 8970131712 Suitable for Isuzu 24V generator
Applicable models: Isuzu
Reference part number:8970292260 8970131710 8970131712 114366 LR240405 8970292260 ALH4366YX ALTV021
| Rated output : | 24V 40A |
| Pulley : | 1pk |
| Size : | 24*18*17cm single unit inner box |
| Weight : | NET WEIGHT:6KG GROSS WEIGHT:6.35KG |
| Packaging : | Neutral kraft paper packaging |
| Spot/Pre sale : | Spot goods |
| Warranty : | 1 year |
| Product number : |
| Type : | ACgenerator |
| Specification : | 24V 40A |
| Pulley : | 1PK |
| Brand : | NUO JIN |
| Number : | 8970292260 8970131710 |
| Quality : | Renovate |
| Delivery time : | 10days |





Installation Method for 24V 40A Isuzu Generator
I. Pre-installation Preparation
Tool and Material List
Tools: Torque wrench (matched with generator fixing bolts), socket wrench, Phillips/flathead screwdriver, combination pliers, insulating tape, multimeter.
Materials: Generator of the specified specification (24V 40A), new generator fixing bolts, lock washers, wire connectors, original factory sealing gaskets (if oil pipelines are involved).
Pre-installation Safety Operations
Turn off the engine and disconnect the negative battery cable to prevent short circuit during installation.
Clean oil stains and rust on the surface of the generator mounting bracket to ensure tight fit.
Inspect the appearance of the new generator: check that the rectifier, regulator and pulley are free from damage, the terminals are not oxidized, and the rotor rotates smoothly without jamming or abnormal noise.
II. Step-by-step Installation Process
1. Mechanical Fixation
Place the generator on the engine mounting bracket and align the bolt holes.
Insert the locating bolt first (do not tighten it), then install the remaining fixing bolts with lock washers to ensure the generator is centered.
Use a torque wrench to tighten the bolts according to the original factory torque standard (the torque of generator fixing bolts for most Isuzu models is 22–28 N·m; refer to the vehicle maintenance manual for the exact value).
Install the generator belt: mount the belt on the pulley, adjust the belt tension (the deflection should be 10–15 mm when pressing the middle part of the belt), then tighten the tensioner bolt.
2. Electrical Connection (24V System)
Critical Note: The 24V system consists of two 12V batteries connected in series. Distinguish between positive and negative poles during wiring; reverse connection is strictly prohibited.
B+ Terminal: Connect the B+ terminal (thick cable connector) of the generator to the main positive battery circuit. Install a lock nut at the connector, wrap it with insulating tape after tightening.
Excitation Wire (D+ or F Terminal): Connect the generator excitation terminal to the vehicle charging indicator light or voltage regulator control circuit, ensuring the plug is fully inserted and not loose.
Ground Wire: Check the ground connection between the generator housing and the engine block. If the grounding is poor, install a dedicated ground wire to ensure an unobstructed current loop.
3. Post-installation Commissioning
Reconnect the negative battery cable and start the engine.
Observe the charging indicator light: the light should turn off at idle speed, indicating the generator is generating electricity normally; if the light remains on, check the wiring or generator for faults.
Use a multimeter to measure the output voltage: the voltage should be 27–28.5 V at idle speed, and stabilize at around 28 V when the engine speed rises to 2000 rpm, which meets the 24V system standard.
Check the belt operation status: ensure there is no slipping, abnormal noise or deviation, and the generator housing has no abnormal vibration.
Precautions for Installation of 24V 40A Isuzu Generator
I. Pre-installation Precautions
Compatibility Verification
Confirm that the generator model matches the vehicle's engine model (e.g., different Isuzu engines such as 4JB1, 4HK1, and 6HK1 correspond to different generator models). Check that the mounting holes, pulley specifications, and wiring terminal definitions are consistent.
Inspect the generator appearance: ensure the rectifier, voltage regulator are free from damage, the rotor rotates smoothly without jamming or abnormal noise, and the terminals are not oxidized or deformed.
Safety Protection Preparation
Must disconnect the negative battery cable to prevent short circuits caused by metal tools touching the terminals during installation.
Clean oil stains and debris in the work area to avoid tool slippage that may damage the generator or engine components.
Wear insulating gloves to prevent arc burns caused by short circuits in the 24V system.
II. Mechanical Installation Precautions
Bolt Fastening Specifications
Use original-specification fixing bolts, equipped with lock washers (spring washers or thread-locking adhesive), and tighten them gradually in a diagonal sequence.
Strictly follow the torque standard: the torque of Isuzu generator fixing bolts is usually 22–28 N·m; refer to the original factory maintenance manual of the corresponding vehicle model for the exact value. Insufficient torque will cause vibration and abnormal noise, while excessive torque may lead to bolt breakage or bracket deformation.
Belt Installation and Tension Control
The belt model must match the generator pulley; mixing different specifications of belts is prohibited.
Tension adjustment standard: press the middle part of the belt (mid-span point) by hand, the deflection should be 10–15 mm. Excessively tight belts will accelerate generator bearing wear, while loose belts will cause slipping and insufficient power generation.
Start the engine after installation and observe the belt operation status to ensure there is no deviation, slipping, or abnormal noise.
Position Calibration
III. Electrical Connection Precautions
Strict Prohibition of Reverse Polarity Connection
The 24V system consists of two 12V batteries connected in series. Clearly distinguish between positive and negative poles: connect the generator's B+ terminal to the main positive battery circuit, and connect the housing ground to the negative battery circuit.
Reverse connection will directly burn out the rectifier and voltage regulator, and may even cause a line fire.
Wiring Terminal Handling
Install a lock nut on the thick cable connector of the B+ terminal; wrap it with insulating tape or heat-shrink tubing after tightening to prevent oxidation and electric leakage.
Fully insert the plug of the excitation wire (D+ or F terminal) and avoid loose connection. A loose connection will prevent the generator from exciting, resulting in the charging indicator light staying on continuously.
Ensure the ground wire is reliably connected between the generator housing and the engine block. If grounding is poor, install a dedicated ground wire (with a cross-sectional area of not less than 10 mm²); otherwise, power generation voltage fluctuations and abnormal equipment operation may occur.
Prohibition of Improper Operations
Do not disconnect the battery cable while the engine is running, as this will generate an instantaneous high voltage that may damage the generator's electronic components.
Do not touch the positive and negative terminals of the generator simultaneously with metal tools to avoid short circuits that burn out components.
References:
I. Original Factory Technical Documents (Highest Priority)
- Isuzu Vehicle/Engine Original Maintenance Manual (corresponding versions for engines such as 4JB1, 4HK1, 6HK1, 4LE2X, etc.)
Core Basis: Torque of generator fixing bolts (22–28 N·m), mounting hole positioning, belt model and tension standards, electrical wiring schematic diagrams, and compatible model comparison tables.
Obtaining Channels: Authorized Isuzu dealers, official technical support platforms, and original factory maintenance manual database.
- Isuzu Generator Spare Parts Manual
Core Basis: Definitions of generator terminals such as B+, D+/F, specifications of lock washers, models of seals, etc.
II. National Standards and Industry Specifications
| Standard Number | Standard Name | Core Applicable Content |
|---|---|---|
| GB/T 2820.5-2009 | Reciprocating Internal Combustion Engine Driven Alternators - Part 5: Test Methods | Test and judgment standards for 24V generator output voltage, load characteristics, etc. |
| GB/T 156-2017 | Standard Voltages | Nominal voltage and voltage deviation specifications for 24V electrical systems |
| JT/T 324-2015 | Automotive Electrical System Maintenance Specifications | General operation guidelines for generator installation, wiring and commissioning |
| SAE J3226-2022 | Voltage Regulation and Limitation | Voltage regulation and steady-state/transient voltage characteristic standards for commercial vehicle 24V power generation systems |
III. Explanation of Key Technical Parameter Sources
Torque Standard (22–28 N·m): Derived from the maintenance manuals of mainstream Isuzu models (e.g., 4JA1, 4JB1 series engines). For some older models, the torque may be 3.6–4.6 kgf·m (approximately 35–45 N·m), which shall be subject to the maintenance manual of the corresponding model.
Belt Deflection (10–15 mm): Referenced from the general specifications for the installation of automotive engine accessory belts, combined with the design requirements of Isuzu engine belt drive systems.
Output Voltage (27–28.5 V): Based on the charging voltage standard of 24V electrical systems, complying with the voltage regulation requirements for 24V generators specified in GB/T 2820.5-2009 and SAE J3226.
Electrical Safety Rules (e.g., strict prohibition of reverse connection, no battery disconnection during operation): Derived from the general safety specifications for automotive 24V electrical systems, and also in line with the design requirements of Isuzu generator electrical systems.

