
23100-F4211 LR165-116 A5T06891 23100-0M003 LR170-746 NISSAN GENERATOR
Applicable models:NISSAN
Reference part number:23100-F4211 LR165-116 A5T06891 23100-0M003 LR170-746 11623100F4211/ LR165116 23100-F420A 23100 F420A 23100F420A 13334N 100181 23100 F4211/ LR165
| Rated output : | 12V 65A |
| Pulley : | 6pk |
| Size : | 24*18*17cm single unit inner box |
| Weight : | NET WEIGHT:5.15KG GROSS WEIGHT:5.4KG |
| Packaging : | Neutral kraft paper packaging |
| Spot/Pre sale : | Spot goods |
| Warranty : | 1 year |
| Product number : |
| Type : | ACgenerator |
| Specification : | 12V 65A |
| Pulley : | 6PK |
| Brand : | NUO JIN |
| Number : | 23100-F4211 LR165-116 |
| Quality : | Renovate |
| Delivery time : | 10days |





Although the installation method of the 12V generator for Nissan vehicles varies slightly by model, the overall process is similar. Below is a widely applicable step-by-step guide, supplemented with practical details for common Nissan models such as the new Sylphy: Pre-Installation Preparation Park the vehicle on a flat surface and engage the handbrake. Turn off the engine and wait for a period of time to allow high-temperature components in the engine compartment to cool down, avoiding burns during operation. Prepare tools including a ratchet wrench, socket set, torque wrench, jack, and safety stands. Confirm that the new 12V generator matches the vehicle model. Disconnect the negative battery terminal to cut off power to the entire vehicle, eliminating the risk of electric shock or short circuit during installation. For models with a car audio security code, confirm the code in advance before disconnecting the power to prevent the audio system from being locked. Initial Fixing of the New Generator Place the new generator in the installation position in the engine compartment (the generator is located on the right front side of the engine for most Nissan models). Reinstall the through-bolt at the bottom of the generator, screw on the nut without fully tightening it to leave space for subsequent adjustments. Then install the tensioner bolt with fixing and adjusting functions at the top of the generator: first screw on the horizontal bolt, snap the vertical bolt into the adjustment slot, and slightly tighten the horizontal bolt. Connecting Electrical Wiring Install the positive cable of the generator, check the installation direction, initially attach the fixing bolt, and do not tighten it yet. Reconnect the generator signal wire connector, ensuring it is securely locked to avoid signal abnormalities due to looseness. During subsequent tightening, it is recommended to use a torque wrench to tighten the fixing nut of the positive cable to 18 Newton-meters. Installing and Adjusting the Drive Belt Tension According to the winding path recorded during disassembly, sequentially fit the drive belt over the crankshaft pulley, water pump pulley, and generator pulley, ensuring the belt fits tightly on all pulleys. Adjust the vertical bolt of the tensioner to adjust the belt tension by pressing down the generator. The appropriate tension standard is that the belt can be easily bent to approximately 90 degrees by hand, or the downward deflection at the longest span of the belt is between 6-12 millimeters. Avoid excessive slack (which may cause slipping) or excessive tightness (which will accelerate bearing wear). Tightening All Bolts Use a torque wrench to tighten all bolts in accordance with specifications. For most Nissan models, the tightening torque for the top fixing bolt of the generator and the nut of the bottom through-bolt can be controlled at around 22-23 Newton-meters. Recheck all bolts to prevent omissions and looseness, avoiding vibration of the generator during operation. Final Inspection Lower the vehicle (if it was jacked up earlier), reconnect the negative battery terminal, and tighten the terminal nut. Start the vehicle and observe if the charging indicator light on the instrument panel turns off. If it turns off, the generator is initially functioning normally. Use a multimeter to test the output voltage: the normal output voltage of a 12V generator under standard operating conditions should be between 13.5-14.5V. You can also turn on full-load equipment such as the air conditioner and headlights; if the voltage does not drop below 13V, it is normal. During operation, listen for abnormal noises such as "squeaking" (belt slipping) or "buzzing" (bearing wear). If any abnormalities are detected, stop the vehicle immediately to check the belt tension or generator installation. The core precautions for installing the 12V generator in Nissan vehicles revolve around safe operation, component compatibility, assembly precision, and functional verification. They also take into account the requirements of special models such as start-stop and hybrid vehicles to avoid electrical failures or component damage: 1. Safe Operation Bottom Lines Disconnect the negative battery terminal throughout the entire installation process. Live work is prohibited to prevent short circuits that could burn out the generator or vehicle ECU. Perform operations only after high-temperature components in the engine compartment (exhaust pipe, turbocharger) have cooled to room temperature to avoid burns. Keep tools away from fuel lines and high-voltage wires to prevent collisions and leaks. For models with a car audio security code, confirm the code in advance before disconnecting the power, or maintain power supply via a diagnostic tool to prevent the audio system from being locked. 2. Component Compatibility and Preprocessing The new generator must be fully compatible with the vehicle model. Verify the part number (Nissan generator part numbers mostly start with "23100-"), power (mostly 80-150A), mounting holes, and terminal type to avoid installation issues due to mismatched models. Inspect the new generator before installation: ensure the brush length is ≥5mm, the bearing is free of jamming, the rotor rotates smoothly, remove oxide layers from terminal surfaces, and apply a small amount of conductive paste to enhance contact stability. When removing the old generator, take photos to record the belt routing and wiring connection positions, especially for models with multiple wire harnesses, to avoid incorrect wiring or reverse belt wrapping during installation. 3. Key Assembly Details Tighten bolts in accordance with torque standards: 18N・m for the positive cable nut, and 22-23N・m for the generator fixing bolts/nuts. Excessive looseness will cause vibration and abnormal noise, while excessive tightness may lead to thread stripping or mounting bracket damage. Install the drive belt strictly following the original routing. Adjust the tension to "easily bend 90 degrees by hand" or a deflection of 6-12mm. Older models such as Sylphy and Teana can be slightly tighter, while new models with start-stop function need to be looser to avoid affecting the start-stop system. Connect the signal wire connector first, then tighten the positive cable nut. Confirm the connector is securely locked by hearing a "click" sound. Fit an insulating protective cap over the positive terminal to prevent water ingress and short circuits. 4. Post-Installation Verification Points After starting the engine, check if the charging indicator light turns off within 3 seconds. If it remains on, prioritize inspecting the wiring connections (especially the signal wire connector). Test the voltage with a multimeter after 3 minutes of idling: 13.5-14.5V is normal. Turn on full-load equipment such as air conditioning and headlights; the voltage should not drop below 13V, otherwise the belt may be too loose or the regulator may be faulty. Listen for no abnormal noises during operation, such as "squeaking" (belt slipping) or "buzzing" (bearing wear). After a short test drive, recheck bolt tightness and belt tension. References: The precautions regarding the installation of the 12V generator for Nissan vehicles you previously inquired about do not have a single unified source. Relevant content is scattered across Nissan model-specific maintenance manuals, technical articles on automotive repair platforms, and general generator technical guides. The specific correspondences are as follows: Nissan Model-Specific Maintenance Manuals Overseas model-specific manuals: Documents such as the Nissan Sentra Service Manual on nisentra.com, the generator disassembly and assembly instructions for the Nissan Almera Classic on the Карпедия platform, and generator-related maintenance documents for Nissan models like the Primera and Patrol on AutoManuals.biz all mention precautions including disconnecting the negative battery terminal during installation, tightening generator bolts in a specific sequence, and checking belt tension and generating voltage after installation. These serve as direct technical bases for the installation of the corresponding models. These manuals specify installation details tailored to the structure of each model. For example, some models require temporarily tightening bolts in a "bottom-to-top" order, followed by final tightening in a "top-to-bottom" order, along with other special operational specifications. Technical Articles on Domestic Automotive Repair Platforms Multiple generator-related technical materials published on the Qiche Dashi (Auto Master) platform summarize general installation precautions applicable to domestic Nissan models. Practical reminders such as avoiding collisions with other engine compartment components during disassembly and assembly, checking for wire insulation damage and short circuits, and controlling bolt tightness are more aligned with the actual needs of ordinary repair scenarios, helping maintenance personnel quickly grasp core points. General Generator Technical Service Guides General technical documents like the Generator Technical Service Guide on Jinchutou Library are not limited to Nissan models. However, their content regarding generator power matching, standard wiring for battery positive and negative terminals, and preventing component damage caused by failing to turn off switches after engine shutdown is equally applicable to Nissan 12V generators. These provide general theoretical support for component compatibility and electrical safety during installation.

