
starter 3690807 2874672 3690807 5575819 4081235 M125R3014SEP STP2999ML,M125R3014SEP M125R3014SEP、M128R3638SE FOR Cummins
Applicable models:Cummins
Consult now
Reference part number: 2874672 3690807 5575819 4081235 M125R3014SEP STP2999ML,M125R3014SEP M125R3014SEP、M128R3638SE 3690807 2874672 4081235 2874672 3690807 2874672 3690807 5575819 2874672 3690807 5575819 2874672 3690807 5575819
Product Attributes
| Power horsepower : | 24V 9KW |
| Number of feet : | 11T |
| Size : | |
| Weight : | Net weight 18.1KG |
| Packaging : | Neutral kraft paper packaging |
| Spot/Pre sale : | Spot goods |
| Warranty : | 1 year |
| Product number : |
Product Details
| Type : | Starter Motor |
| Specification : | 24V 9KW |
| Number of feet : | 11T |
| Brand : | NUOJIN |
| Number : | 3690807 |
| Quality : | Remanufacture |
| Delivery time : | 30 days |






The Cummins 24V 9KW starter is mostly compatible with its engine series such as ISC and ISB. Its installation must conform to the high-pressure and high-torque characteristics of diesel engines, with strict control over positioning accuracy and wiring specifications. The detailed installation method sorted out by integrating official maintenance key points and practical operation experience is as follows:
Pre-installation Preparation
- Safety and Tool PreparationPark the vehicle or equipment on a flat surface and secure it firmly. Disconnect the negative cable of the storage battery to eliminate the risk of short circuits. Wear non-slip gloves and safety goggles. Prepare a torque wrench (which must be calibrated in advance), cleaning cloths, terminal cleaner, and high-temperature grease. Meanwhile, have a multimeter ready for subsequent circuit testing. In addition, verify the condition of the storage battery. It is required that the battery capacity is no less than 180Ah and the CCA (Cold Cranking Amps) rating is 1300A to prevent insufficient power supply from affecting post-installation tests.
- Component and Mounting Surface InspectionConfirm that the starter model is compatible with the engine (e.g., model 8200101 and other applicable models). Check that the starter has a voltage of 24V and a power of 9KW, with no external damage. Manually toggle the drive gear to ensure it can extend and retract smoothly. Thoroughly wipe off oil stains, rust, and residues from the starter mounting surface on the engine housing using a cleaning cloth. If the mounting surface is deformed, repair it first before installation. Ensure that the starter remains parallel to the flywheel ring gear without deviation after installation.
Core Installation Operations
- Pre-installation LubricationApply an appropriate amount of high-temperature grease to the starter's drive gear, the sliding surface of the one-way clutch, and the shift fork of the solenoid switch to enhance operational smoothness. Inject a proper amount of lubricating oil into the solenoid switch to ensure its engaging action is flexible. Be careful not to get grease on the electrical components such as the solenoid switch contacts, as this may cause poor contact.
- Starter Alignment and FixationAlign the gear end of the starter with the flywheel ring gear. Ensure that the axis of the starter is parallel to the flywheel ring gear after installation, and that the distance between the end face of the starter gear and the end face of the engine ring gear is controlled within 4±1 millimeters. Insert 2 - 3 fixing bolts after aligning with the mounting holes, and tighten them in stages in a diagonal sequence. For M12 - specification bolts, the recommended tightening torque is 25 - 30N・m, while for some engine models, the tightening torque of the fixing bolts shall be implemented as 137±7N・m. Avoid excessive or insufficient torque, which may lead to housing cracking or operational vibration.
- Standardized Wiring ConnectionFor the power cable (thick wire), use a conductor with a cross-sectional area of more than 50 square millimeters, connect it to the "B+" terminal of the solenoid switch, and fit an insulating sleeve over it. For the control cable (thin wire), select a conductor with a cross-sectional area of no less than 2.5 square millimeters and connect it to the "S" terminal of the solenoid switch. Clean the oxide layer on the connection terminals during wiring to ensure firm joints without poor contact. In addition, keep the wires as short as possible to reduce current loss.
Final Testing and Commissioning
- Component ResetAfter confirming that the wiring connections are correct, reconnect the negative cable of the storage battery. Check that there is no wire entanglement and no wires are in contact with high-temperature components such as the exhaust pipe. Ensure no debris is left in the surrounding area.
- Functional TestingConduct an ignition start test. The duration of a single start should be controlled within 5 seconds. If the start fails, wait for at least 30 seconds before attempting again to avoid overheating and damage to the starter. During startup, listen for any abnormal noises and observe that the drive gear can engage and retract normally. A multimeter can be used to detect the storage battery voltage drop during startup; the normal voltage drop should be no more than 3V. Meanwhile, check that the starter maintains a stable speed during idle operation and that there are no issues such as gear jamming.
Precautions for Installing the Cummins 24V 9KW Starter
The Cummins 24V 9KW starter is suitable for diesel engine series such as ISC and ISB, which feature high rotational speed and high torque. During the installation process, priority should be given to avoiding risks like short circuits, component misalignment, and torque loss of control. The core precautions sorted out from the aspects of safety protection, component operation, wiring connection, inspection and commissioning are as follows to ensure the starter operates in proper coordination with the engine:
I. Safety Protection: Prevent High-Voltage and Mechanical Hazards
Mandatory Power Disconnection and Circuit Protection
Throughout the entire installation process, the negative cable of the storage battery must be disconnected first. If the equipment is equipped with a dual-battery pack, the negative poles of both battery packs should be disconnected simultaneously. It is strictly prohibited to plug or unplug wires or fasten components while the power is on. When conducting a temporary test on the solenoid switch, the single power-on duration shall not exceed 3 seconds to avoid overheating and burnout of the coil. Insulated gloves must be worn during the test to prevent metal tools from accidentally touching the "B+" terminal and the housing, which could cause a short circuit.Use terminal cleaner to remove the oxide layer from the battery terminals. Ensure the bolts are tightened properly during connection (with a torque of approximately 8N・m) to prevent the terminals from overheating and melting when large current passes through. The installation area should be kept away from flammable parts such as diesel pipelines and fuel tank vents to prevent safety accidents caused by electric sparks from the circuit.
Mechanical Safety and Equipment Fixation
When installing the starter on heavy-duty equipment (such as construction machinery), professional jacks combined with non-slip pads should be used to secure the machine body. Operation is strictly prohibited when the equipment is tilted. The starter weighs about 15 - 20kg; during installation, a bracket should be used or two people should cooperate to lift it. Avoid carrying it with one hand, as this may lead to component collisions or hand injuries from falling.The engine must be in a fully cooled state (with the engine block temperature ≤ 40℃). Do not touch high-temperature components such as the exhaust pipe and turbocharger to prevent scalding. Before removing the old starter, mark the routing of the wires in advance to avoid incorrect wiring during the installation of the new one.
References:
Source of Precautions for Installing the Cummins 24V 9KW Starter
The precautions for installing the Cummins 24V 9KW starter you obtained earlier are not derived from a single exclusive official document or authoritative source of Cummins. Instead, they are integrated from official maintenance key points related to Cummins engines, universal industry installation specifications, and practical experience of accessory manufacturers. The reference bases corresponding to the core information are detailed as follows:
1. Cummins-Related Official and Original Factory Supporting Maintenance Materials
A number of key technical parameters and basic specifications in the precautions correspond to official materials such as the Chongqing Cummins Engine Spare Parts Maintenance Manual. For example, requirements including:
The distance between the end face of the starter gear and the end face of the engine ring gear being controlled within 4±1 mm;
The battery meeting the standards of capacity ≥ 180Ah and CCA (Cold Cranking Amps) rating of 1300A;
The cross-sectional area of the power cable being larger than 50 mm² and that of the control cable being no less than 2.5 mm²;
All these are consistent with the standardized installation indicators in the manual. Meanwhile, the safety requirement in the manual—disconnecting the negative battery cable before installation to prevent accidental startup—also aligns with the safety protection key points summarized in the precautions. In addition, some details such as torque standards and component compatibility are consistent with the dedicated installation specification directions for starters in Cummins engine series like QSK.
2. Universal Industry Specifications for Starters in Automotive and Construction Machinery Fields
Requirements in the precautions, such as the time limits for startup tests (single startup ≤ 5 seconds, interval between failed attempts ≥ 30 seconds) and the need to clean the mounting surface during installation to avoid uneven stress on components, match the universal installation guidelines for Cummins starters in the industry.
For instance, the requirement to lubricate only moving parts (e.g., drive gears, one-way clutches) and strictly prohibit contamination of solenoid switch contacts and coils is a common practical key point in the installation of high-power starters for diesel engines, as it prevents component functional failure.
Furthermore, wiring taboos like avoiding close bundling of control cables and power cables to prevent electromagnetic interference comply with the universal electrical specifications for the installation of diesel generator set electrical systems in the industry.
Related Articles
Can you install an auto starter in any vehicle? Learn how Auto Starter installation works, which cars are compatible, and how manufacturer production and factory supply ensure reliable performance for modern vehicles.....
Discover what vehicles use auto starter systems and how Auto Starter car technology improves safety, convenience, and performance. Learn about manufacturer production, factory supply, and modern applications for cars, trucks, and commercial vehicles.....
Looking for a complete Auto Starter guide? This article explains how auto starters work, types, symptoms, maintenance tips, and how manufacturers and factories supply high-quality starters for global production and bulk orders.....
Learn everything about starter parts, how they work, signs of failure, maintenance tips, and how a professional manufacturer with factory production ensures stable, high-quality starter components for global vehicle owners.....
Explore the real-world Auto Starter disadvantages in industrial and automotive production. Learn how auto starter systems affect reliability, cost, maintenance, and factory manufacturing efficiency.....
Discover what a starter solenoid does in a vehicle, how it works with the starter motor, signs of failure, and why quality starter solenoid production from a professional manufacturer and factory matters for reliable performance.....

