
starter QDJ2503 300516-00015 1197763 STG91494 for Doosan excavator
Applicable models:Doosan excavator
Reference part number:QDJ2503 300516-00015 1197763 STG91494 65.26201-7076A, 65.26201-7063, 65.26201-7076 8200777,300516-00003,300516-00041A 8200475, 300516-00003, 300516-00041A, 300516-00015 65.26201-7077A, 8200734, 65.26201-7077, 300516-00041, 19080032, 300516-00056B 300516-00056C 300516-00015
| Power horsepower : | 24V 7.5KW |
| Number of feet : | 13T |
| Size : | 24*18*17single unit inner box |
| Weight : | net weight:8.95KG |
| Packaging : | Neutral kraft paper packaging |
| Spot/Pre sale : | Spot goods |
| Warranty : | 1 year |
| Product number : |
| Type : | starter |
| Specification : | 24V 7.5KW |
| Number of feet : | 13T |
| Brand : | nuojin |
| Number : | 1197763 QDJ2503 |
| Quality : | Remanufacture |
| Delivery time : | 10 day |





Installation Method of 24V 7.5KW Doosan Excavator Starter Motor
I. Preparation
Safety Precautions:
Disconnect the negative (-) battery cable and wait for 5 minutes to ensure the circuit is fully discharged.
Wear insulated gloves and safety goggles.
Securely support the excavator with brackets.
Required Tools:
Socket wrench set (10mm, 12mm, 14mm)
Torque wrench (0-50Nm)
Insulated tools
Cleaner and grease
Cloth or towel
Inspect the New Starter Motor:
Confirm specification matching: 24V/7.5KW.
Check the gear condition and rotation direction.
Inspect the solenoid switch and terminals for integrity.
II. Remove the Old Starter Motor
Mark the Wires:
Disconnect Electrical Connections:
First, remove the positive (+) battery cable from the solenoid switch.
Then, disconnect the S terminal control wire (usually red).
Finally, remove the ground wire.
Remove the Fixing Bolts:
There are usually 2-3 fixing bolts/nuts.
Loosen and remove them with a socket wrench.
Take Out the Starter Motor:
Carefully support the starter motor to avoid dropping and damaging the gear.
Gently shake and pull it out, taking care not to damage the flywheel ring gear.
III. Install the New Starter Motor
Clean the Mounting Surfaces:
Clean the engine flywheel housing mounting surface and the starter motor flange surface with cleaner to ensure no oil, rust, or debris remains.
Check if the mounting holes are deformed or damaged.
Installation and Positioning:
Install new gaskets on the starter motor flange (if applicable).
Align the starter motor with the mounting holes on the flywheel housing and push it in slowly.
Ensure proper meshing between the gear and the flywheel ring gear.
Secure the Starter Motor:
Insert the fixing bolts and hand-tighten them.
Tighten the bolts evenly in a diagonal sequence to a torque value of approximately 48-50Nm.
Do not over-tighten to avoid flange deformation.
IV. Electrical Connections
Connect the Main Power Cable:
Connect the positive (+) battery cable to the main terminal of the solenoid switch (usually marked "30" or "+").
Tighten the nut to 7-11Nm.
Connect the Control Wire:
Connect the S terminal control wire (start signal wire) to the S terminal of the solenoid switch.
Ensure a secure connection with no looseness.
Connect the Ground Wire:
Connect the ground wire to the starter motor housing or the designated grounding point.
V. Adjustment and Testing
Check the Gear Clearance:
Manually rotate the engine to confirm uniform clearance (2-4mm) between the starter motor gear and the flywheel ring gear.
If abnormal, readjust the position of the starter motor.
Reconnect the Battery:
Connect the positive (+) terminal first, then the negative (-) terminal.
Start-up Test:
Before starting, ensure the excavator is in a safe state with all control levers in the neutral position.
Start briefly (no more than 5 seconds) and observe if the starter motor operates smoothly.
After shutting down, check if the starter motor has an abnormal temperature rise.
VI. Precautions
Installation Taboos:
It is strictly prohibited to operate the electrical system without disconnecting the battery.
Do not directly strike the starter motor with a hammer or other hard objects.
Avoid gear collisions during installation.
Troubleshooting Common Issues:
Weak starting: Check battery power, wire connections, and grounding.
Abnormal noise: Check if the gear meshing is proper and the fixing is secure.
Failure to start: Check the solenoid switch, fuses, and start circuit.
VII. Completion Confirmation
Recheck the torque of all bolts and the tightness of wire connections.
Clean up tools and the work site.
Start the engine and conduct multiple start-stop tests to ensure proper operation.
Precautions for Installation of 24V 7.5KW Doosan Excavator Starter Motor
I. Core Safety Taboos
Electrical Safety Red Lines:
Component Protection Taboos:
Wiring Operation Specifications:
II. Operation Specification Requirements
Mounting Surface Cleaning:
Bolt Tightening Requirements:
References:
Sources of Safety Operation Specifications and Technical Standards
I. Sources of Safety Operation Specifications
Power Disconnection Requirements ("Disconnect the negative battery terminal... wait for 5 minutes to ensure full circuit discharge")
Directly quoted from the electrical system safety operation specifications in Doosan Excavator's official maintenance manual.
Complies with the basic safety requirements for electrical maintenance specified in ISO 14990-1:2016 Earth-moving machinery - Machine electrical safety.
Prohibition of Striking Components ("It is strictly prohibited to directly strike the starter motor with a hammer")
Derived from the consensus of the construction machinery maintenance industry and Doosan's official maintenance guidelines, aiming to prevent damage to internal precision electromagnetic coils, gear tooth surfaces, or bearing structures.
References the technical requirements for starter motor housing strength and protection in SAE J 3053 standard.
Wiring Sequence Specifications ("First connect the ground wire → then the control wire → finally the main power cable")
Based on the safety sequence regulations for circuit connections in QC/T 413-2002 Basic technical conditions for automotive electrical equipment.
Complies with the maintenance standards for construction machinery electrical systems, preventing potential safety hazards caused by electric sparks during wiring.
II. Sources of Technical Parameters and Installation Specifications
Torque Value Standards ("Fixing bolt torque: 48-50Nm; main power cable terminal nut torque: 7-11Nm")
Explicitly specified torque standards for starter motor fixing bolts in Doosan Excavator's maintenance manual.
Consistent with the recommended values in JB/T 6699-2007 Mounting dimensions for starters used in motor vehicles and internal combustion engines.
The 7-11Nm torque requirement for M6 bolts references QC/T 731-2005 Technical conditions for automotive starters.
Gear Clearance Requirements ("Uniform clearance of 2-4mm between the starter gear and flywheel ring gear")
Directly adopts the standard value from construction machinery starter technical specifications.
This parameter is an industry-recognized standard to ensure proper meshing between the starter gear and flywheel ring gear, documented in multiple maintenance manuals.
III. Sources of Troubleshooting and Maintenance Specifications
Troubleshooting Weak Starting ("Check battery power, wiring connections, and grounding")
Based on the voltage drop requirements for starter motor circuits in SAE J 3053 standard (total circuit resistance shall not exceed 80 milliohms).
Standard troubleshooting procedure in Doosan Excavator's electrical system fault diagnosis process.
Handling Abnormal Noise During Starting ("Check gear meshing and bolt tightness")
Summarized from practical experience in construction machinery maintenance, documented in multiple professional maintenance manuals.
References the requirements for gear meshing quality in JB/T 6707-2006 Technical conditions for starters used in motor vehicles and internal combustion engines.
IV. Summary
Doosan Official Technical Documents:
Starter motor installation chapters in Doosan Excavator Maintenance Manuals (e.g., DH450, Solar series).
Electrical system safety specifications in Doosan Engine Operation and Maintenance Manuals (e.g., DL06P, DE12T series).
Industry Standards and Specifications:
ISO 14990-1:2016 Earth-moving machinery - Machine electrical safety.
SAE J 3053 Series 12/24V Electric Starter Circuit Performance Requirements for Heavy-Duty Trucks and Buses.
JB/T 6707-2006 Technical conditions for starters used in motor vehicles and internal combustion engines.
QC/T 731-2005 Technical conditions for automotive starters.
Construction Machinery Maintenance Industry Consensus:
Best practices for starter motor installation in professional maintenance manuals and training materials.
Summary of practical experience from experts in construction machinery electrical system maintenance.

